Roth C, Gangl C, Kreiner G, Delle Karth G
Two Different Mechanisms of Very Late Stent Thrombosis: Assessment and Guidance of Therapy with Optical Coherence Tomography
Journal für Kardiologie - Austrian Journal of Cardiology 2014; 21 (11-12): 314-317

Volltext (PDF)    Summary    Übersicht   

Abb. 1a-b: LAD Aktuelles Bild - Abb. 2a-d: OCT Abb. 3a-b: LAD Abb. 4a-d: OCT
Abbildung 2a-d: OCT
Representative OCT images. (a, b): Malapposed stent struts with thrombi; (c): uncovered stents struts; (d): covered stent struts; (e): graphical representation of stent coverage, areas with one or more uncovered struts are represented by red lines.
 
OCT
Vorheriges Bild Nächstes Bild   


Abbildung 2a-d: OCT
Representative OCT images. (a, b): Malapposed stent struts with thrombi; (c): uncovered stents struts; (d): covered stent struts; (e): graphical representation of stent coverage, areas with one or more uncovered struts are represented by red lines.
 